6.15 Copy between heads
You can copy between heads using the keypad. To copy the head data, select some heads from the
keypad, press COPY and then enter the destination heads. For example, to copy from heads 1 to 2 to
heads 5 to 8
1 THRU 2 COPY 5 THRU 8 ENTER
Selected attributes can be copied rather than the entire head, by using SHIFT + COPY instead of COPY
and setting the attribute mask.
It is not necessary to have the same number of source heads as destination heads. Each of the source
heads is used in turn to copy data to the destination heads.
6.16 Head Macros
The console loads macros for the head from the personality file. Typical macros are "Lamp On",
"Lamp Off" and "Reset" - however they are very head dependent.
The "Lamp On", “Lamp Off andReset macros can be run at any time by using the following short-
cuts:
SHIFT + LOCATE Lamp on selected heads
CTRL + LOCATE Reset selected heads
CTRL + SHIFT + LOCATE Lamp off selected heads
Other head macros can be accessed in the Macro Window - press the HEAD MACRO soft button. A list
of the available macros is displayed. Select the macro you wish to run. Progress of the macro is shown
in the Status Window.
It is also possible to lamp on or off all fixtures from the MACRO window.
6.17 Selecting individual Heads
When programming it is often useful to be able to control one head out of a group of heads - for
instance, in order to set up it's position on the stage. Alternatively you may wish to apply an effect
to all the heads, such as fanning the position.
The head control buttons situated to the right of the touch screen enable the individual head to be
selected quickly. Once a number of heads have been selected for programming, the head control
buttons controls how changes are applied to those heads. By default changes are applied to all the
selected heads.
6.17.1 Locate
Pressing LOCATE, locates all the selected heads. The personality data for each head specifies what
happens to a head when it is located. Typically the shutter is opened, the dimmer is set to 100% and
pan and tilt are set to the centre position.
Pressing SHIFT LOCATE applies the lamp on macro to heads which have a lamp on functionality.