42.15.8 Serial remote protocol
Determines what protocol is used on the serial port. If set to “none” then any data received is ignored. Data can be transmitted
from the Macro field of Cue steps in the Cue Stack.
The other protocols are:
ChamSys Rem (rx)
ChamSys Rem (tx & rx)
ChamSys Rem (tx)
Ideal Touch
A1 Touch
Elo Touch
The Touch protocols are for the use of external RS232 serial touch screens with the MQ50, MQ100, MQ200 and MQ300
consoles. Refer to the instruction manual of your touch screen for other serial settings.
See Controlling MagicQ Using Serial Port and Multiple Consoles for more details.
42.15.9 Serial touch monitor
Determines which monitor on the MagicQ system has a touch screen connected to the serial port.
42.15.10 Remote trigger type
This setting specifies how the remote input port on MagicQ consoles, MagicQ PC Wings and MagicQ Maxi Wings works.
It can be set to None, Make, Break, or Make + Break.
42.15.11 Remote trigger action
This setting specifies specific global actions to be taken on a remote trigger input. The options are:
The options are:
NONE
CURRENT PLAYBACK GO
CURRENT PLAYBACK FLASH
ADD/SWAP
SWAP
DBO
WING1 PB1 GO
WING1 PB1 FLASH
WING1 PB12 GO
WING1 PB12 FLASH
PB10 GO